5. SYSTEM CONNECTOR INTERFACE

28

LZT 123 7589 R1A

Hard Shutdown Sequence

Figure 5.4 Hard Shutdown Sequence

(4) To implement the Hard Shutdown of the GR47, the ON/OFF pulse must

be held low until the sequence is complete. Ensure that ON/OFF is not

released before VIO has been deactivated by the module.

5.6.1 VIO - 2.75V Supply

VIO provides an output voltage derived from an internal 2.75V regulator.
Its electrical characteristics are shown below.

You can use this output for the following:

• to indicate that the radio device is powered;

• to power interface circuits, external to the radio device.

ON/OFF

VIO

t

HSD

t

PULSE

Symbol

Parameters

Conditions

Min.

Typ

Max

Unit

t

+6'

Time to complete

hardware

shutdown

2

-

11

s

t

38/6(



Application ON/

OFF pulse width

ON/OFF low

until VIO is

disabled

t

+6'

10

-

s

Parameter

Min.

Typ.

Max.

Units

Output Voltage (I

load

= 50 mA)

2.70

2.75

2.85

V

Load current

75

mA