Electrical grounding instructions: (continued) – Bostitch CAP1512-OF User Manual

Page 6

Advertising
background image

ELECTRICAL GROUNDING INSTRUCTIONS: (continued)

DUTY CYCLE:
To ensure long life of your BOSTITCH air compressor, do not operate on more than a 50% duty
cycle. If this air compressor pumps air more than 50% of one hour, then the compressor’s
capability is less than the air delivery required by the application. Always match the air
volume requirements of the attachment or accessory with the air volume delivery of the
compressor.

Notice!: BOSTITCH does not recommend the use of extension cords with compressors. The
use of an extension cord can result in the loss of voltage supplied to the compressor which
could prevent the compressor from starting. For optimum performance, plug the compressor
directly into an outlet and increase the length of airline as needed.

If an extension cord must be used, use these guidelines:

Distance Needed

Recommended Gauge

Less than 25 ft.

12 Gauge

25 - 50 ft.

10 Gauge

Greater than 50 ft.

Not Recommended

6

CAP1512-OF

SPECIFICATIONS

Motor:

2HP (Peak) / 1.5HP (Running)
115V – 60HZ

Fuse Requirements:

15 Amps minimum

Operating Pressure:

0 – 150PSI

Safety Valve Setting:

160 PSI

Air Delivery:

3.7 CFM @ 40 PSI

2.8 CFM @ 90 PSI

Maximum Amps at Working Pressure:

12

Tank Size:

1.2 Gallons

Air Outlet:

1/4" NPT

Pressure Switch Settings:

On @ 120 PSI

Off @ 150 PSI

Weight:

22lbs.

PSI = Pounds Per Square Inch:

CFM = Cubic Feet Per Minute

Advertising