Power Cord Safety

Please read the following safety information carefully before installing the switch:
Warning: Installation and removal of the unit must be carried out by qualified personnel only.
• The unit must be connected to an earthed (grounded) outlet to comply with international

safety standards.

• Do not connect the unit to an A.C. outlet (power supply) without an earth (ground)

connection.

• The appliance coupler (the connector to the unit and not the wall plug) must have a

configuration for mating with an EN 60320/IEC 320 appliance inlet.

• The socket outlet must be near to the unit and easily accessible. You can only remove power

from the unit by disconnecting the power cord from the outlet.

• This unit operates under SELV (Safety Extra Low Voltage) conditions according to

IEC 60950. The conditions are only maintained if the equipment to which it is connected
also operates under SELV conditions.

• When using an AC-power module, the customer must provide a 20 A listed circuit breaker

on the branch circuit. When using a DC-power conversion module, a listed circuit breaker
or other appropriate disconnect device must be provided as part of the building installation.

France and Peru only
This unit cannot be powered from IT

supplies. If your supplies are of IT type, this unit must

be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary
connection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

Important! Before making connections, make sure you have the correct cord set. Check it
(read the label on the cable) against the following:

Power Cord Set
U.S.A. and Canada

The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:

- No. 18 AWG - not longer than 2 meters, or 16 AWG.

- Type SV or SJ

- 3-conductor
The cord set must have a rated current capacity of at least 10 A
The attachment plug must be an earth-grounding type with NEMA

5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

Denmark

The supply plug must comply with Section 107-2-D1, Standard

DK2-1a or DK2-5a.

Switzerland

The supply plug must comply with SEV/ASE 1011.

U.K.

The supply plug must comply with BS1363 (3-pin 13 A) and be

fitted with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of

type HO3VVF3GO.75 (minimum).