ROUBLESHOOTING

A-2

Link LED is Off

Network cable or

Ethernet device

attached to this port

may be defective.

• Verify that the switch and

attached device are powered
on.

• Be sure the cable is plugged

into both the switch and
corresponding device.

• Verify that the proper cable

type is used and its length does
not exceed specified limits.

• Check the adapter on the

attached device and cable
connections for possible
defects. Replace the defective
adapter or cable if necessary.

Major LED is Red

Major alarm

detected.

• One or more major system

alarm(s) affecting traffic have
occurred. Check the alarm
filter mask to determine
potential cause(s) of alarm.

Minor LED is

Amber

Minor alarm

detected.

• One or more minor system

alarm(s) affecting traffic have
occurred. Check the alarm
filter mask to determine
potential cause(s) of alarm.

Fan Fail LED is Red

Fan failure

• One or more fans in the fan

tray have failed. Replace the
fan tray.

Table A-1 Diagnosing Switch Indicators (Continued)

Symptom

Possible Cause

Action