Schumacher PI-1500 User Manual

Page 11

Advertising
background image

- 10 -

inverter to reset. To reset: press the “TeST” button (stops

flow of electricity to outlet) on the outlet face. Next, press

the “RESET” button (restores flow of electricity to outlet)

on the outlet face.

LeDs and Audio Alarms

Green – Power on

Red light and/or Audio Alarm

Current overload – Red led glows for a short time and

inverter shuts down. Current load too high for inverter.

Reduce current demand.

Voltage overload – Red led glows and inverter shuts

down. Voltage range of 15.5V ± 0.5V dC too high for

inverter. Voltage exceeding 16 volts may damage the

inverter. Reduce voltage range to 12 volts to 14 volts.

Voltage Shortage – Alarm sounds indicating voltage is

getting low (10.5V ± 0.3V dC). Inverter shuts down and

red light glows when voltage falls below 10.0V ± 0.3V dC.

Inverter needs voltage source between 12 volts and 14

volts.

Temperature overload – Red led glows for a short time

and inverter shuts down. Provide ample ventilation for

inverter to restart.

Analogic output Power display - shows AC continuous

power consumed. Five lights indicate half of the continu-

ous output power and ten lights indicate full continuous

Advertising