background image

- 14 -

StAGe 2: The inverter then converts the 145-volts dC

into 110-volts AC (household voltage) using advanced

MOSFET transistors in a full bridge configuration. A "modi-

fied sine wave" waveform is generated by this conversion.

troubleshooting

PRoBLeM: Low or No output Voltage

Reason/Solution

1. Poor contact at terminals.

Unhook and rehook the 12-volt connections.

2. Using incorrect type of voltmeter to test output

voltage.

Use a true RMS reading meter.

PRoBLeM: Red LeD on

Reason/Solution

1. Battery voltage below 11 volts.

Recharge or replace battery.

2. equipment being operated is drawing too much

power.

Use a higher capacity inverter or do not use this

equipment.

3.

Inverter is too hot (thermal shut down mode).

Allow inverter to cool. Check for adequate ventilation.

Reduce the load on the inverter to rated continuous

power output.

Advertising