background image

IR Security & Safety

575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax

P/N: M053-016-A

http://www.irsupport.net

Page 10 of 15

2.2 Connecting the PIM-485-16-TD-NXT to a Star I/II Access Control

Unit

Note: Make certain that that Star I/II Terminal Block TB1 is configured for the S-NET
communication protocol.

2.2.1 PIM-485-16-TD-NXT using an Original PIM PCB

Star I/II – TB1

PIM-485-16-TD-NXT – J6

SNET A

A

SNET B

B

Table 2-3 – RS485 Connection: Original PIM PCB & RAMM

2.2.2 PIM-485-16-TD-NXT using a RS485 PIM PCB

Star I/II – TB1

PIM-485-16-TD-NXT – J6

SNET A

TA- & RA-

SNET B

TB+ & RB+

Table 2-4 – RS485 Connection: RS485 PIM PCB & RAMM

Note: The Star I/II has a 2 wire RS-485 interface therefore the PIM’s J6 TA- & RA- must be
connected and the PIM’s J6 TB+ & RB+ must be connected.