ROOFTOP SRT80-120NE

ROUGH-IN-DIMENSIONS

GAS VALVE PIPING

SRT80-120

1/2" NPT

Recovery capacities are based on heater performance at 80% thermal efficiency.

Table 1. RECOVERY CAPACITIES - NATURAL GAS / L.P.

Approx.

BTU

Gallon

Model

Input

Capacity

30

40

50

60

70

80

90

100

110

120

130

140

SRT80-120

120,000

80

388

291

233

194

166

145

129

116

106

97

90

83

35.17 kwh

303L

(1469)

(1102)

(882)

(734)

(628)

(549)

(488)

(439)

(401)

(367)

(341)

(314)

TEMPERATURE RISE - DEGREES °F - GALLONS PER HOUR (LPH)

FRONT VIEW

TOP VIEW

LEFT SIDE VIEW

RIGHT SIDE VIEW