* In case of multiple error, last error is displayed.

[SENSOR POSITION]

• ERROR CODE SCREEN DISPLAY

* Error code will be displayed on center of screen.

E 11 B

E 11 B

R. G. B

SENSOR NUMBER

ERROR CODE 10

ERROR

3

0

1

2

SCREEN

0 : UPPER SENSOR

1 : LEFT SENSOR

2 : RIGHT SENSOR

3 : LOWER SENSOR

• ERROR CODE DISPLAY IN REGI SERVICE MODE

PJE 2 9 1 4 0
ERR

ITEM NUMBER-29

ERROR CODE 40

SENSOR NUMBER
(ONLY "10"or "20")

R.G.B

G-0 (Blank)
R-1
B-2

3-11. AUTO REGISTRATION ERROR CODE LIST

00

No Error

10

Sensor Output Level Low

* Check wiring, beam position, sensor.

0 : Upper Center

1 : Middle Left

2 : Middle Right

3 : Lower Center

20

Sensor Output Level High

* Check OP-amp circuit.

0 : Upper Center

1 : Middle Left

2 : Middle Right

3 : Lower Center

30

Adjustment Loop Counter Overflow

* Check the registring information on the convergence board.

40

Regi Data Overflow

* Check the convergence yoke driver ICs.

50

Regi Data Overflow

60

Offset Overflow

* Convergence patterns displayed are out of normal range.

70

Offset Overflow

ERROR

DISCRIPTION

NOTE

CODE

[ERROR CODE LIST]

If an error code is displayed after the set has been fully adjusted, correctly, please check the following items: position, tilt and sizing. If

either of these adjustments are off, even slightly, the auto-registration pattern will not hit the four sensors properly. This occurs when the

internal generator patterns is being flashed on the screen for the sensors to read. Therefore, auto registration (called auto-focus) cannot

operate properly causing an error code to be displayed. In order for this function to operate properly, correct position, tilt and size must be

adjusted properly.