KP-43T75A/53SV75A

RM-Y906

RM-Y906

Remove the cap off from
the unused terminal and
cpmmect a static voltmeter
there.

SECTION 4

SAFETY RELATED ADJUSTMENTS

[ G BOARD]

Fig. 4-1

4-1. HV REGULATION CIRCUIT CHECK AND

ADJUSTMENT

When replacing the following components marked with

on the schematic diagram always check HV regulation, and
if necessary re-adjust.

:

C517

:

C517, C521, C522

IC654, L504
T502, T504 (FBT)
D.Y, A board, G board

OPERATION CHECK

1. Connect a HV static voltmeter to the unconnected plug of

the high-voltage block. (Fig.4-1)

2. Power on the set.
3. Receive the dot signal. (PICTURE and BRIGHTNESS to

minimum)

4. Check that the HV static voltmeter is reading 31.00

+0.95

kVdc.

-1.45

HV Regulation adjustment

1. Connect a HV static voltmeter to the unconnected plug of

the hight-voltage block.

2. Power on the set.
3. Receive the dot signal. (PICTURE and BRIGHTNESS to

minimum)

4. If anode voltage is 31.95kV or higher, replace C517 of 470PF/

2kV with that of 680PF/2kV, and check if the voltage is within
the standard range.

5. If anode voltage is 29.66kV or lower, replace C517 of 470PF/

2kV with that of 100PF/2kV, and check if the voltage is within
the standard range.

4-2. HV HOLD DOWN CIRCUIT OPERATION

CHECK AND ADJUSTMENT

When replacing the following components marked with

on the schematic diagram always check hold-down voltage
and if necessary re-adjust.

:

R536, R545

:

C516, C536

D506, D507, D522
IC206, IC502, IC654
L504, R511, R522, R536, R538, R545,
R548, R584
T502, T504 (FBT)
D.Y, A board, G board

OPERATION CHECK

HV HOLD-DOWN ADJUSTMENT

1. Repeat steps 1 ~ 7 as above.
2. If hold down voltage is 34.45kV or higher, remove R536,

mount a resistor (150k

, 1/4W : RN) onto R545 instead, and

check again if the hold-down voltage is within the standard
range.

3. If hold down voltage is 32.55kV or lower, mount a resistor

(220k

, 1/4W : RN) onto R536 and check again if the hold-

down voltage is within the standard range.

NOTE : Please finish the adjustment as soon as possible

4-3. +B MAX VOLTAGE CONFIRMATION

The following adjustments should always be performed when
replacing IC654.
1. Supply 130VAC to with variable autotransformer.
2. Input a dot signal.
3. Set the PICTURE control and the BRIGHTNESS controls to

minimum.

4. Confirm the voltage of G BOARD TP135V is less than

137.0Vdc.

5. If step 4 is not satisfied, replace IC654 and repeat above steps.

1. Remove CN652 connecter.
2. Short-circuit across TP-PROT and ground.
3. Connect a HV static voltmeter to the unconnected plug of

the high-voltage block.

4. Connect a 220

/ 200W variable resistor, across pin 2 and

pin 1 of CN652 and connect an external dc power supply
unit (200V, class 2A) to pin 3 of CN652.

5. First turn on the external power supply (+B=135V), then

turn on the power of the set.

6. Receive the dot signal. (PICTURE and BRIGHTNESS to

minimum)

7. Gradually increase the value of the external dc power supply

and check that the hold-down circuit operates at a static
voltmeter reading of 33.5

±

0.95kVdc when the raster

disappears.