Connectivity rules, 1000 mbps gigabit ethernet collision domain, Connectivity rules -6 – SMC Networks SMCBGSLCX1 User Manual

Page 34: 1000 mbps gigabit ethernet collision domain -6

Advertising
background image

N

ETWORK

P

LANNING

2-6

Connectivity Rules

When adding hubs (repeaters) to your network, please follow the
connectivity rules listed below for Ethernet, Fast Ethernet, and Gigabit
Ethernet. However, note that because switches break up the path for
connected devices into separate collision domains, you should not include
the switch or connected cabling in your calculations for cascade length
involving other devices.

1000 Mbps Gigabit Ethernet Collision Domain

Note:

Although maximum cable length for 100BASE-FX fiber depends
on the duplex mode, the maximum length for 1000BASE-X fiber
is the same for both half and full duplex.

Maximum 1000BASE-T Gigabit Ethernet Cable Length

Cable Type

Maximum Cable Length

Category 5, 5e 100-ohm UTP or STP

100 m (328 ft)

Maximum 1000BASE-SX Fiber Optic Cable Distance

Fiber Diameter

Fiber Bandwidth

Cable Length Range

62.5/125 micron

multimode fiber (MMF)

160 MHz/km

2-220 m (7-722 ft.)

200 MHz/km

2-275 m (7-902 ft.)

50/125 micron MMF

400 MHz/km

2-500 m (7-1641 ft.)

500 MHz/km

2-550 m (7-1805 ft.)

Maximum 1000BASE-LX Fiber Optic Cable Distance

Fiber Diameter

Fiber Bandwidth

Cable Length Range

9/125 micron single-mode

fiber (SMF)

N/A

2 m - 5 km (7-16,404 ft)

Advertising