3. As each connection is made, the green Link LED (on the TigerSwitch)

corresponding to each port will light to indicate that the connection is
valid.

Wiring Closet Connections

Today, the punch-down block is an integral part of many of the newer
equipment racks. It is actually part of the patch panel. Instructions for
making connections in the wiring closet with this type of equipment
follow.

1. Attach one end of a patch cable to an available port on the switch, and

the other end to the patch panel.

2. If not already in place, attach one end of a cable segment to the back

of the patch panel where the punch-down block is located, and the
other end to a modular wall outlet.

3. Label the cables to simplify future troubleshooting.

Figure 4-2. Wiring Closet Connections

Equipment Rack
(side view)

SMC TigerSwitch 10/100

Patch Panel

Punch-Down Block

Wall

T ig er S w it ch 10 /1 0 0

6 7 2 4 L 3