Environmental specifications, Certification, Environmental specifications certification – Sony Ericsson GM29 User Manual

Page 17

Advertising
background image

Technical Data

17

Environmental specifications

Certification

Operating temperature range

–25 °C to +55 °C

Storage temperature range

–40 °C to +85 °C

Relative humidity

5 - 95%, non-condensing

Stationary vibration,
sinusoidal

Displacement: 7.5 mm
Acceleration amplitude: 20 m/s² and 40m/s²
Frequency range: 2-8 Hz, 8-200Hz, 200-500Hz

Stationary vibration, random

Acceleration spectral density (m²/s²):
0.96, 2.88, 0.96
Frequency range:
5-10Hz, 10-200 Hz, 200-500 Hz, 60min/axis

Non-stationary vibration,
including shock

Shock response spectrum I, peak acceleration:
3 shocks in each axis and direction; 300m/s², 11 ms.

Shock response spectrum II, peak acceleration:
3 shocks in each axis and direction; 1000m/s², 6 ms.

Bump

Acceleration: 250 m/s²

Free fall transportation

1.2m

Rolling pitching
transportation

Angle: ±35degrees; period: 8s

Static load

10kPa

Low air pressure/high air
pressure

70kPa/106kPa

Directive
1999/5/EC

EMC: EN 301 489-1

EMC: EN 301 489-7

Safety: EN 60950

GSM 3GPP TS 51.010-1

Tested according to GCF-CC