Installation

5

Installation

Safety and Installation
Information

[Needs to be checked and re-written]

The Terminal should be installed and setup
only by qualified personnel.

Connect a fast 1.25A fuse to the incoming
line for the positive supply voltage to
protect the Terminal.

If a power supply unit is used to supply the
GM29 modem, it must meet the demands
placed on SELV circuits in accordance
with EN60950. When using batteries and
accumulators, adhere to the relevant
regulations.

The maximum permissible connection
length between the GM29 Modem and the
supply source is 3m.

Your supplier will be pleased to provide
you with a detailed technical description
and technical support for the GM29
Modem.

Securing the Modem

NOTE! Before securing the modem take into

account the amount of additional space
required for the mating connectors and
cables that will be used in the
application.

NOTE! Where access is restricted, it may be

easier to connect all the cables to the
modem prior to securing it in the
application.

Securely attach the GM29 modem to the host
application using two 3mm diameter pan-head
screws of appropriate length as shown below.

CAUTION! Do not over tighten the fixings

screws. Excessive torque applied
to the screws can crack the plastic
case.

Fixing Screws