Three wire range cord connection, Disconnect electrical power at breaker box – Siemens HE2528U User Manual

Page 13

Advertising
background image

Installation

English 9

6. Remove ground strap from CENTER post, rotate so that wide end is at TOP

and attach wide end to range through hole below junction box. Attach GREEN
wire on TOP of ground strap. Tighten Screw.

8. Attach RED wire, round washer, star washer and nut IN THIS ORDER to

LEFT post.

9. Attach WHITE wire, round washer, star washer and nut IN THIS ORDER to

CENTER post.

10. Attach BLACK wire, round washer, star washer and nut IN THIS ORDER to

RIGHT post.

12. Tighten all connections securely and replace terminal block cover.
13. Properly secure strain relief. See “Install Strain Relief” on page 6.

Note:
DO NOT plug in range at this time.

Three Wire Range Cord Connection

The Four Wire Connection (above) is preferred, but where local codes and ordi-
nances permit grounding through neutral and where conversion to four wire is
impractical, the unit may be connected to the power supply via a three wire con-
nection.

1. Disconnect electrical power at breaker box.

Figure 7: Four Wire Range Cord Connection - Ground Strap and Wire

Figure 11: Four Wire Range Cord Connection (continued)

ground strap

green ground screw

ground wire

red

white

black

Advertising