Installation

English 10

2. Remove the terminal block cover to expose the terminal block.

4. Remove TOP nut, star washer, and round washer from each post.

Note:
DO NOT remove last round washer, last nut or internal wiring leads.

5. Attach WHITE wire, round washer, star washer and nut IN THIS ORDER on

TOP of ground strap on CENTER post.

6. Attach RED wire, round washer, star washer and nut IN THIS ORDER to

LEFT post.

7. Attach BLACK wire, round washer, star washer and nut IN THIS ORDER to

RIGHT post.

9. Tighten all connections securely and replace terminal block cover.

11. Properly secure strain relief. See “Install Strain Relief” on page 6.

Figure 3: Terminal Block

Figure 8: Three Wire Connection

Figure 10: Completed Three Wire Range Cord Connection

red

white

black

ground strap

green ground screw