16. Properly secure flexible conduit at knockout on angle and at supply side junc-

tion box. The wiring is now complete.

Note:
DO NOT plug in range at this time.

Three Wire Flexible Conduit Con-

nection

The Four Wire Connection is preferred, but where local codes and ordinances
permit grounding through neutral and/or conversion to four wire is impractical, unit
may be connected to the power supply via a three wire connection.

1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the terminal block.

4. Remove the TOP nut, star washer, and round washer from each post.

Note:
DO NOT remove last round washer, last nut or internal wire leads.

5. Place one terminal lug (packaged with this manual) on each post. Replace the

star washer and round washer and secure with 20 inch pounds of torque.

6. Strip 3/8 (9.53 mm) inches of insulation from the end of each wire.

Figure 17: Completed Four Wire Flexible Conduit Connection

red wire

white wire

green

ground

screw

black wire

green ground wire

Figure 3: Terminal Block

Figure 7: Wire Stripping

3/8 “