Southbend DMS-30 User Manual

Page 2

Advertising
background image

1100 Old Honeycutt Road, Fuquay-Varina, NC 27526

(919) 762-1000 www.southbendnc.com

Models:

Form DMT Rev 1 (November/2010)

DMT-30

DMT-40

DMT-60

DMS-30

DMS-40

DMS-60

INTENDED FOR COMMERCIAL USE ONLY.

NOT FOR HOUSEHOLD USE

.

M

odel

S

hipping

W

eight

M

iniMuM

C

learanCe

C

apaCity

u

nitS

a

B

C

d

e

F

g

DMT-30

475 lbs. [215 kg]

SIDES

BACK

0

0

30 Gallons

(114 liters)

inches

(mm)

24”

(610)

36”

(914)

16”

(406)

39”

(991)

37.25”

(946)

41.5”

(1054)

65.25”

(1657)

DMS-30

375 lbs. [170 kg]

DMT-40

525 lbs. [238 kg]

40 Gallons

(151 liters)

inches

(mm)

26”

(660)

36”

(914)

15”

(381)

40”

(1016)

38.38”

(975)

42.5”

(1080)

68.25”

(1733)

DMS-40

400 lbs. [181 kg]

DMT-60

600 lbs. [272 kg]

60 Gallons

(227 liters)

inches

(mm)

29.5”

(749)

42”

(1067)

16”

(406)

43”

(1092)

41.12”

(1045)

47.62”

(1210)

74.25”

(1886)

DMS-60

500 lbs. [227 kg]

SERVICE CONNECTIONS

– COLD WATER: 3/8” O.D. tubing to faucet.

– HOT WATER: 3/8” O.D. tubing to faucet.

– DRAIN: 1-5/8” (41.275 mm) O.D. tubing piped to open floor drain. No solid connection.

– ELECTRICAL CONNECTION: (DMT models only) 1/2” conduit connection to controls. Unless otherwise

specified, field wire electrical connection to be 120V, 60 Hz, single Phase, 10 Amps with grounding wire.

– STEAM SUPPLY: 3/4” (19 mm) IPS for incoming steam. MIN 5PSI (34kPa), MAX 35 PSI (241 kPa).

Important: Pressure reducing valve required if incoming steam pressure exceeds the kettle rating.

DIMENSIONS