The ModelSource 640-pin Adapter

Labeling the Daughterboard

After you have completed the Shell Software and mounted the Adapter and
Daughterboard onto the ModelSource modeling systems, you must verify the
Daughterboard’s label and update it if necessary.

Note

Ensure that the Daughterboard is seated on the Adapter before you verify
and update the label. If the daughterboard is not seated, the software will
report the label as “GEN640”, the label of the Adapter itself.

If it is necessary to update the Daughterboard’s label, use the lm Label Device Adapter
utility to change the adapter’s label to the device_name used in the model’s Shell
Software. For more details, refer to “Label Device Adapter“ in the

ModelSource User’s

Manual

.

Verifying the Model

After you have developed the model, you must verify it. For more information, see the

ModelSource User’s Manual

and the

Logic Model Development Manual

.

Note

The pattern memory available for simulation is limited to the smallest
amount of available memory on any one of the eight modeling boards in the
four modelers.

Advertising