1 software setup, 2 mobilarm status – Standard Horizon MAX CPF180I User Manual

Page 100

Advertising
background image

Page 102

CPF180i and CPF300i

NOTE

Note the CPF180i only has one NMEA input so Port 1 will have to be set to MOBILARM. The

CPF300i has 3 ports so port 1, 2 or 3 can be be used.

Port 1 Example

Chart Plotter

MOBILARM

Blue

NMEA Out

Brown

NMEA In

Red

GPS V+

Black

GPS V-

NOTE

Refer to the Figure 16.0, the Blue and Brown wires are from Port 1. If these wires are being used

to connect to another NMEA device, choose another wire pair and configure the port associated

with the wires.

16.1 SOFTWARE SETUP

After the Port has been chosen and connected in Par. 16.0, the GPS Chart Plotter must be
setup to communicate with the MOBILARM.
Use the steps below to set up the Port the MOBILARM is connected to the GPS Chart Plotter.
1. Select the Chart page.
2. Press [MENU]. Move the ShuttlePoint knob to highlight SETUP MENU and press [ENT].
3. Move the ShuttlePoint knob to highlight ADVANCED SETUP and press [ENT] or move

the ShuttlePoint knob to the right.

4. Move the ShuttlePoint knob to highlight IN/OUT CONNECTIONS and press [ENT] or

move the ShuttlePoint knob to the right.

5. Move the ShuttlePoint knob to highlight any input port and press [ENT] or move the

ShuttlePoint knob to the right.

6. Move the ShuttlePoint knob up/down to select MOBILARM and press [ENT] or move

the ShuttlePoint knob to the right. Selecting MOBILARM format, activates the function.

7. Press [CLR] or move the ShuttlePoint knob to the left until the Chart page is shown.

The GPS Chart Plotter continuously verifies the communication status with MOBILARM PTX
(Personal Transponder) device. When a signal from the PTX is lost for more than one minute,
the MOBILARM sends a NMEA message to the GPS Chart Plotter which will produce an alarm
and a popup window will be shown on Standard Horizon GPS Chart Plotter.

16.2 MOBILARM STATUS

To confirm the status of the MOBILARM, select the About page:
1. Select the Chart page.
2. Press [MENU] two times. Move the ShuttlePoint knob to highlight About... and press

[ENT].

On the About page you can see the status of the MOBILARM, below are the possible
messages.

a. Function not Activated

: MOBILARM has not been setup in the I/O Connections

menu. Refer to Par. 16.1.

b. Not connected/detected : possible wiring problem, confirm wires are correct con-

Advertising
This manual is related to the following products: