Absolute maximum ratings, 1 absolute maximum dc ratings, 2 dram component operating temperature range – Samsung M391B5773DH0 User Manual

Page 11: Ac & dc operating conditions, 1 recommended dc operating conditions (sstl-15), Datasheet, Ddr3l sdram, Unbuffered dimm

Advertising
background image

- 11 -

datasheet

DDR3L SDRAM

Rev. 1.0

Unbuffered DIMM

9. Absolute Maximum Ratings

9.1 Absolute Maximum DC Ratings

NOTE :
1. Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the

device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions
for extended periods may affect reliability.

2. Storage Temperature is the case surface temperature on the center/top side of the DRAM. For the measurement conditions, please refer to JESD51-2 standard.
3. V

DD

and V

DDQ

must be within 300mV of each other at all times;and V

REF

must be not greater than 0.6 x V

DDQ

, When V

DD

and V

DDQ

are less than 500mV; V

REF

may be

equal to or less than 300mV.

9.2 DRAM Component Operating Temperature Range

NOTE :
1. Operating Temperature T

OPER

is the case surface temperature on the center/top side of the DRAM. For measurement conditions, please refer to the JEDEC document

JESD51-2.

2. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. During operation, the DRAM case temperature must be main-

tained between 0-85

°C under all operating conditions

3. Some applications require operation of the Extended Temperature Range between 85

°C and 95°C case temperature. Full specifications are guaranteed in this range, but the

following additional conditions apply:

a) Refresh commands must be doubled in frequency, therefore reducing the refresh interval tREFI to 3.9us. It is also possible to specify a component with 1X refresh (tREFI

to 7.8us) in the Extended Temperature Range.

b) If Self-Refresh operation is required in the Extended Temperature Range, then it is mandatory to either use the Manual Self-Refresh mode with Extended Temperature

Range capability (MR2 A6 = 0b and MR2 A7 = 1b), in this case IDD6 current can be increased around 10~20% than normal Temperature range.

10. AC & DC Operating Conditions

10.1 Recommended DC Operating Conditions (SSTL-15)

NOTE:
1. Under all conditions V

DDQ

must be less than or equal to V

DD

.

2. V

DDQ

tracks with V

DD

. AC parameters are measured with V

DD

and V

DDQ

tied together.

3. V

DD

& V

DDQ

rating are determinied by operation voltage.

Symbol

Parameter

Rating

Units

NOTE

V

DD

Voltage on V

DD

pin relative to V

SS

-0.4 V ~ 1.975 V

V

1,3

V

DDQ

Voltage on V

DDQ

pin relative to V

SS

-0.4 V ~ 1.975 V

V

1,3

V

IN,

V

OUT

Voltage on any pin relative to V

SS

-0.4 V ~ 1.975 V

V

1

T

STG

Storage Temperature

-55 to +100

°C 1,

2

Symbol

Parameter

rating

Unit

NOTE

T

OPER

Operating Temperature Range

0 to 95

°C

1, 2, 3

Symbol

Parameter

Operation Voltage

Rating

Units

NOTE

Min.

Typ.

Max.

V

DD

Supply Voltage

1.35V

1.283

1.35

1.45

V

1, 2, 3

1.5V

1.425

1.5

1.575

V

1, 2, 3

V

DDQ

Supply Voltage for Output

1.35V

1.283

1.35

1.45

V

1, 2, 3

1.5V

1.425

1.5

1.575

V

1, 2, 3

Advertising
This manual is related to the following products: