En 2 7 27 charcoal filter (recycling version – Smeg KSE912NX User Manual

Page 11

Advertising
background image

EN

2
7

27

Charcoal filter (recycling version

)

This filter cannot be washed or regenerated. It has to be replaced when the EF appears on the
display or at least once every 4 months.

Activation of the alarm signal
• In the recycling version hoods the filter saturation alarm has to be activated during the in-

stallation or later.

• Switch off the hood and the lights.
• Press the E-key for about 5 seconds until the LED on the display start to move.
• Press the B-key within 5 seconds until a confirmation of the activated state of filter satura-

tion alarm on the display appears:
• 2 flashings on EF - charcoal filter saturation alarm ACTIVATED
• 1 flashing on EF - charcoal filter saturation alarm DEACTIVATED.

SUBSTITUTION OF THE CHARCOAL FILTER

Alarm reset
• Switch off the motor and the lighting system.
• Press the G-key for at least 2 seconds.

Substitution of the filter
• Remove the metal grease filters.
• Remove the charcoal filter as indicated in the picture.
• Place the filter again into its seat.
• Place again the metal grease filters into their place.

Lighting

LIGHT REPLACEMENT

20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it

out of from the Hood.

• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the

two pins are properly inserted in the lamp holder socket holes.

• Refit the Support, fixing it in place with the two screws re-

moved as above.

Advertising