Mounting the hood body

• Before attaching the hood body, tighten the two screws Vr lo-

cated on the hood body mounting points.

• Hook the hood body onto the screws 12a.
• Fully tighten the support screws 12a.
• Adjust the screws Vr to level the hood body.

12a

Vr

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120mm, the
choice of which is left to the installer.

To install a ø 150 pipe
• To install the dumper 10
• Fix the pipe in position using sufficient pipe clamps (not sup-

plied).

To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection, insert the redu-

cer flange 9 on the dumper 10.

• Fix the pipe in position using sufficient pipe clamps (not sup-

plied).

• Remove any activated charcoal filters.

9

ш 120

ш 150

10

10

RECIRCULATION VERSION AIR OUTLET

• Push fit connection 15 onto the hood body outlet.
• Insert the connection extension pieces laterally 14.1 in connec-

tion 15.

• Make sure that the outlet of the extension pieces 14.1 is hori-

zontally and vertically aligned with the chimney outlets. If this
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 and then reassemble as described
previously.

• Ensure that the activated charcoal filters have been inserted.

14.1

15