Figure 4.5 reset_n timing for smbus mode, Table 4.5 reset_n timing for smbus mode, 3 usb bus reset – SMSC USB2512i User Manual

Page 30: Usb bus reset, Datasheet, Reset_n for smbus slave configuration

Advertising
background image

Industrial Temperature Rated USB 2.0 High-Speed 2-Port Hub Controller

Datasheet

Revision 1.92 (11-28-07)

30

SMSC USB2512i

DATASHEET

4.6.2.3

RESET_N for SMBus Slave Configuration

Figure 4.5 Reset_N Timing for SMBus Mode

Notes:

„

For Bus-Powered configurations, the 99.5ms (MAX) is required, and the Hub and its associated
circuitry must not consume more than 100mA from the upstream USB power source during
t2+t3+t4+t5+t6+t7. For Self-Powered configurations, t3 MAX is not applicable and the time to load
the configuration is determined by the external SMBus host.

„

All Power Supplies must have reached the operating levels mandated in

Chapter 5, DC

Parameters

, prior to (or coincident with) the assertion of RESET_N.

4.6.3

USB Bus Reset

In response to the upstream port signaling a reset to the Hub, the Hub does the following:

Note: The Hub does not propagate the upstream USB reset to downstream devices.

1. Sets default address to 0.

2. Sets configuration to: Unconfigured.

3. Negates PRTPWR[2:1] to all downstream ports.

Table 4.5 Reset_N Timing for SMBus Mode

NAME

DESCRIPTION

MIN

TYP

MAX

UNITS

t1

RESET_N Asserted.

1

μsec

t2

Hub Recovery/Stabilization.

500

μsec

t3

SMBus Code Load (See Note).

250

300

msec

t4

Hub Configuration and USB Attach.

100

msec

t5

Host acknowledges attach and signals USB

Reset.

100

msec

t6

USB Idle.

Undefined

msec

t7

Completion time for requests (with or without data

stage).

5

msec

t1

t2

t4

t5

t6

t7

RESET_N

VSS

Hardware

reset

asserted

Reset

Negation

SMBus Code

Load

Attach

USB

Upstream

USB Reset

recovery

Idle

Start

completion

request

response

t3

Hub PHY

Stabilization

Advertising