Chapter 5 dc parameters, 1 maximum guaranteed ratings, 2 recommended operating conditions – SMSC USB2512i User Manual

Page 32: Maximum guaranteed ratings, Recommended operating conditions, Chapter 5, dc, Parameters, Datasheet

Advertising
background image

Industrial Temperature Rated USB 2.0 High-Speed 2-Port Hub Controller

Datasheet

Revision 1.92 (11-28-07)

32

SMSC USB2512i

DATASHEET

Chapter 5 DC Parameters

5.1

Maximum Guaranteed Ratings

Note: Stresses above the specified parameters could cause permanent damage to the device. This

is a stress rating only and functional operation of the device at any condition above those
indicated in the operation sections of this specification is not implied. When powering this
device from laboratory or system power supplies, it is important that the Absolute Maximum
Ratings not be exceeded or device failure can result. Some power supplies exhibit voltage
spikes on their outputs when the AC power is switched on or off. In addition, voltage transients
on the AC power line may appear on the DC output. When this possibility exists, it is suggested
that a clamp circuit be used.

5.2

Recommended Operating Conditions

PARAMETER

SYMBOL

MIN

MAX

UNITS

COMMENTS

Storage

Temperature

T

A

-55

150

°C

Lead

Temperature

325

°C

Soldering < 10 seconds

1.8V supply

voltage

V

DDA18PLL,

V

DD18

2.5

V

3.3V supply

voltage

V

DDA33,

V

DD33PLL,

V

DD33,

V

DD33CR

4.6

V

Voltage on any

I/O pin

-0.5

5.5

V

Voltage on

XTAL1

-0.5

4.0

V

Voltage on

XTAL2

-0.5

3.6

V

PARAMETER

SYMBOL

MIN

MAX

UNITS

COMMENTS

Operating

Temperature

T

A

-40

85

°C

1.8V supply voltage

V

DDA18PLL

V

DD18

1.62

1.98

V

3.3V supply voltage

V

DDA33

V

DDA33PLL

V

DD33

V

DD33CR

3.0

3.6

V

Voltage on any I/O pin

-0.3

5.5

V

If any 3.3V supply voltage drops

b e l o w 3 . 0 V, t h e n t h e M A X

becomes:

(3.3V supply voltage) + 0.5

Advertising