Troubleshooting guide – Shindaiwa EB802 User Manual

Page 18

Advertising
background image

18

Troubleshooting Guide

Vaporlock.

Engine hot/heat soaked.

Low fuel quality.

Let cool completely and restart.

Refi ll with fresh, clean unleaded gasoline with a pump

octane of 89 or higher mixed with a 2 stroke engine oil that

meets or exceeds ISO-L-EGD and/or JASO FD classifi ed

oils at 50:1 gasoline/oil ratio.

What To Check

Possible Cause

Remedy

ENGINE DOES NOT START OR HARD TO START

NO

NO

NO

NO

Does the engine crank?

Good compression?

Does the tank contain fresh
fuel of the proper grade?

Is fuel visible and moving
in the return line when
priming?

Is there spark at the spark
plug wire terminal?

Check the spark plug.

Faulty recoil starter.

Fluid in the crankcase.

Internal damage.

Loose spark plug.

Excess wear on cylinder,
piston, rings.

Fuel incorrect, stale, or
contaminated; mixture incorrect.

Check for clogged fuel fi lter
and/or vent.

Priming pump not functioning properly.

The ignition switch is in
“O” (OFF) position.

Shorted ignition ground.

Faulty ignition unit.

If the plug is wet, excess
fuel may be in the cylinder.

The plug is fouled or improperly
gapped.

The plug is damaged internally
or of the wrong size.

Consult with an authorized shindaiwa servicing dealer.

Tighten and re-test.

Consult with an authorized shindaiwa
servicing dealer.

Refi ll with fresh, clean unleaded gasoline with a pump
octane of 89 or higher mixed with a 2 stroke engine oil that
meets or exceeds ISO-L-EGD and/or JASO FD classifi ed
oils at 50:1 gasoline/oil ratio.

Replace fuel fi lter or vent as required.
Re-start.

Consult with an authorized shindaiwa
servicing dealer.

Move switch to “I” (ON) position
and re-start.

Consult with an authorized shindaiwa
servicing dealer.

See "Starting a Flooded Engine"

Clean and gap the spark plug. Check the Specifi cations
section for the correct plug and gap for your unit. Restart.

Replace the spark plug. Check the Specifi cations section
for the correct plug and gap for your unit. Restart.

NO

YES

What To Check

Possible Cause

Remedy

ENGINE DOES NOT START

YES

YES

YES

YES

Advertising