RS-232C Command List

XC-555/P

12 pin Connector

1

GND

2

+12 V

3

GND

4

VBS/Y out

5

GND

6

– /HD in

7

VS/VD in

8

GND

9

– /C out

10

TXD (RS-232C)

11

RXD (RS-232C)

12

GND

PC

D-SUB 9P

CD

1

RXD

2

TXD

3

DTR

4

GND

5

DSR

6

RTS

7

CTS

8

RI

9

5

Push the back panel and the CCD head block back
into their previous positions, and tighten the
Philips screws ( 7) to a torque of 0.18 N•m.

Connections

Communication
Specifications

This unit utilizes an RS-232C-compliant, flow
controlled, synchronous serial interface.
Because the RS-232C setting is set to OFF when the
unit is shipped from the factory, you must change the
setting of the internal DIP switches to utilizes the RS-
232C function. (Before changing the settings make
absolutely sure that the power to the unit is turned off.
(See “Setting the RS-232C Switches” (page 11).))

The parameters are as follows.
Communication speed : 9600 bps
Data length

: 8 bit

Stop bit

: 1 bit

Parity

: None

This is a no-flow-control, no-handshake protocol, each
bite is transmitted from the LSB line.

Characters that can be transmitted are ASCII codes
30h to 39h, 41h to 5Ah (Alphabetic capital letters A to
Z, Arabic numerals 0 to 9), a space (20h), and a
Carriage Return (0Dh).
Thus the commands used to control the camera are
made up of the character set specified above, and each
command must end with a Carriage Return character
(0Dh).

Because this is a no-flow-control protocol, to prevent
communication overflows, if the host side sends one
byte, before sending the next byte, insert a 1 ms stop
period.

Advertising
This manual is related to the following products: