Installation of the appliance, 1 electrical connection, Instructions for the installer – Smeg A1-2 User Manual

Page 4

Advertising
background image

Instructions for the installer

38

2. INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by

competent persons.

Corgi gas installers are approved to work to safe and satisfactory

standards. All gas installation, servicing and repair work must be in

accordance with the gas safety regulations 1984 (installation and use) as

amended 1990.

It may be installed against walls one of which is higher than the worktop

surface, at least 50 mm from the side of the appliance, as shown in the

installation class drawings A and B. Wall units or extractor hoods installed

above the appliance's work-top must be at least 750 mm above it.

A

B

SLOT IN FREE STANDING

2.1 Electrical connection

Make sure that the power line voltage matches the specifications
indicated on the rating plate located inside the storage compartment.
This rating plate must never be removed.

The plug at the end of the power cable and the wall socket must be the
same type (conforming to regulations in force). Check that the power line
is adequately grounded. Do not use reducers, adapters or shunts.

On the power line, install an omnipolar cut-off device with contact cut-off
distance greater than or equal to 3 mm, located in an easily accessible
position near the unit.

If the power cable is replaced, the wire

section on the new cable must not be

less than 1.5 mm

2

(3 x 1.5 cable),

keeping in mind that the end to be

connected to the hob must have the

ground wire (yellow-green) longer by at

least 20 mm. Use only the special

cables available at our Service

Centres.