1 adjustment of minimum for natural gas, 2 regulation of minimum for lpg, Final operations – Smeg A1-2 User Manual

Page 8: Instructions for the installer

Advertising
background image

Instructions for the installer

42

4. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the
burner caps and the grids.

After adjustment to a different kind of gas from the one for which the
cooker has been tested, replace the plate inside the storage

compartment with one corresponding to the new kind of gas. This plate

can be obtained from your nearest Authorised Assistance Centre.

4.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum.
Remove the gas tap knob and turn the
adjustment screw inside or at the side of the tap
shaft (depending on the model) until there is a
regular minimum flame. Replace the knob and
check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the
flame should not go out). Repeat the operation on
all the gas taps.

4.2 Regulation of minimum for LPG

For regulating the minimum with LPG, the screw at the side of the tap rod
must be turned clockwise all the way.
The bypass diameters for each individual burner are shown in paragraph
“3.2 Burner and nozzle characteristics table”. Once the regulation has
been completed, replace the seal on the by-passes using paint or similar
materials.