Spectra Watermakers Newport 400 User Manual

Page 43

Advertising
background image

43

SYMPTOMS

PROBABLE CAUSE

REMEDY

Spectra Watermakers Newport Troubleshooting Procedures

Error Messages

“System stalled”

(“system stalled” may alarm
when using the control panel
to run system for servicing
with the pressure relief valve
open– use manual override
switch instead)

- pressure relief valve open
- intake thru-hull closed
- airlocked system
- no signal from flow meter

- Close pressure relief valve
- Check thru-hull
- Check flow meter wiring at con-

trol box

- Replace flow meter

“High Pressure”

- blocked brine discharge
- fouled membrane

- Check brine discharge
- Clean membrane

“Voltage Too High”
“Voltage Too Low”

- battery voltage too high or

low

- loose wires or poor connec-

tions

- Charge batteries
- Check charging voltage
- Check power connections

“Re-starting”

- no signal from flow meter at

startup. System Air-locked

- See remedy above for “system

stalled”

“Check Fuse” (followed by
fuse number)

- blown fuse at circuit board

- Replace fuse (mini automotive

type ATM)

- Look for cause

“Service Prefilter”

- clogged filters
- loose or defective pressure

sensor wires

- Install new filters
- Check sensor wiring

-

s

“Salinity High”

- high product water salinity
- chlorine damage to mem-

branes

- defective salinity probe or

cable, cable disconnected

- Check for low feed pressure
- Check for leaks at high pressure

hoses

- Remove and clean probe con-

tacts check calibration.

- Check cable connections
- Clean membrane