Dehumidification mode – Sharp CV-P10NC User Manual

Page 21

Advertising
background image

ENGLISH

DEHUMIDIFICATION MODE

1

Remove the exhaust hose (See Page 15)

2

Turn the drainage nozzle to the OPEN position.

3

Pull the stopcock out from the drainage nozzle.

• When the stopcock is removed, a small amount of water

may be discharged from the drainage nozzle.

• Always perform this procedure with the unit turned off.

Drain water will spout out if attempted during operation.

4

Attach the drain grommet to a standard commer-

cially-available hose. (5/8" inner diameter, 7/8"
outer diameter)

5

Attach the hose to the drainage nozzle, and se-

cure it with the hose band.

• Insert the hose securely into a container with a minimum

capacity of 3

1/2

gallons. Be sure to monitor the water level

in the container and empty as necessary. Do not operate
in dehumidify mode for more than 8 hours at a time. Be
sure to empty the water container whenever dehumidify
mode is started. Failure to empty the water container can
cause the container to overfl ow and cause damage to un-
derlying materials.

• Set the hose sloping downwards for easier drainage.

Moreover, do not bend the hose at any point, nor allow
the end to be submerged in water.

Dehumidifi cation with no container

E-19

2

1

In this mode, the air conditioner dehumidifi es the room.

CAUTION

When operating dehumidifi cation with container, the unit generates heat during dehumidifi -
cation mode and the room temperature will rise. Operate dehumidifi cation with no container
if you don't want the room temperature to rise. This will help to slightly drop the room tem-
perature, but dehumidifi cation performance will become less effective than when operating
dehumidifi cation with container.

1

Press the MODE button to select DEHU-

MIDIFICATION mode.

COOL

DEHUM

FAN

VENT

2

Press the power button to start operation.

• The red OPERATION lamp on the unit will light.
• The temperature cannot be set.
• The fan speed is preset to AUTO and cannot be

changed.

TO TURN OFF

Press the POWER button again.

• The red OPERATION lamp on the unit will turn off.

Dehumidifi cation with container

Drainage nozzle

Stopcock

Drain grommet

Hose

I

f draining of the water is not desirable, install the exhaust hose (See Page 14), turn the drainage nozzle to the

CLOSE position, and check that the drainage nozzle is covered with the stopcock. In this operation, the water
tank inside the unit may be full, the unit stops operating and then the TIMER, OPERATION and MEGA COOL
lamps are blinking, depending on room condition. In this case, drain out the water within the unit (See Page
27).

"OPEN" position

Hose band

Advertising