Drainage – Sharp CV-P10NC User Manual

Page 29

Advertising
background image

ENGLISH

DRAINAGE

Prepare for drainage and drain out water within the unit in the following cases.

If the unit stops operating and the TIMER, OPERATION and MEGA COOL lamps are
blinking. (This indicates that the water tank inside the unit is full.)

1

Make sure to turn the unit off.

2

Turn the drainage nozzle to the OPEN position.

3

Pull the stopcock out from the drainage nozzle.

• When the stopcock is removed, a small amount of water

may be discharged from the drainage nozzle.

4

Attach the drain grommet to a standard

commercially available hose. (5/8" inner di-
ameter, 7/8" outer diameter)

5

Attach the hose to the drainage nozzle, and

secure it with the hose band.

• Prepare for draining, as drain water will come out

through the hose during operation.

6

Press the POWER button on the unit twice.

• The water will drain out through the drainage hose.

Maximum amount of water that may be drained out is

approximately 4

1/5

pints.

• The OPERATION, TIMER and MEGA COOL lamps will

be blinking.

7

When drainage water stops running out

from the hose, turn the unit off by pressing
POWER button.

• This will take about one minute.

Whenever the unit is moved (to prevent water within the unit from spilling).
When the unit is not used for a long time.

1

Carry out the above procedures from 1 to 5.

2

Press the POWER button on the unit.

• The water will drain out through the drainage hose.

Maximum amount of water that may be drained out is approximately 4

1/5

pints.

• The OPERATION lamps will light.

3

When drainage water stops running out from the hose, turn the unit off by

pressing POWER button.

• This will take about one minute.

4

Remove the hose from the drainage nozzle, and replace the stopcock.

• Keep the hose clamp and drain grommet in case of re-used.

5

Turn the drainage nozzle to the CLOSE position.

6

Remove the stopcock from the drainpipe nozzle, and completely drain any

water within the unit.

• Always prepare a receptacle to collect the water before

draining. Maximum amount of water that may be drained

out is approximately

2/5

pints.

7

Replace the stopcock to the drainpipe nozzle.

E-27

Stopcock

Drainpipe nozzle

Drainage nozzle

Stopcock

Drain grommet

Hose

"OPEN" position

Hose band

8

Remove the hose from the drainage nozzle, and replace the stopcock.

• Keep the hose band and drain grommet in case of re-used.

9

Turn the drainage nozzle to the CLOSE position.

Advertising