Seagate MEDALIST PRO ST36530N/W/WC User Manual

Page 4

Advertising
background image

2

Medalist Pro Installation Guide, Rev. B

Electrostatic discharge protection

Caution. Removal of circuit boards by personnel not perform-

ing depot repair will damage components and may
void the warranty.

All drive electronic assemblies are sensitive to static electricity,
due to the electrostatically sensitive devices used within the
drive circuitry. Although some devices such as metal-oxide semi-
conductors are extremely sensitive, all semiconductors, as well
as some resistors and capacitors, may be damaged or degraded
by exposure to static electricity.

Electrostatic damage to electronic devices may be caused by the
direct discharge of a charged conductor or by exposure to the
static fields surrounding charged objects. To avoid damaging
drive electronic assemblies, observe the following precautions
when installing or servicing the drive:

• Ground yourself to the drive whenever the drive electronics

are or will be exposed. Connect yourself to ground with a wrist
strap (Seagate part number 12263496). Connection may be
made to any grounded metal assembly. As a general rule,
remember that you and the drive electronics must all be
grounded to avoid potentially damaging static discharges.

• Turn off the power before removing or installing the DC power

cable.

• Do not remove any circuit boards from the drive.

• Never use an ohmmeter on any circuit boards.

• When installing the drive on a carrier or tray, discharge the car-

rier or tray prior to inserting it into the system.

Advertising
This manual is related to the following products: