Source Technologies ST9620 User Manual

Page 37

Advertising
background image

Source Technologies, LLC ST9620 Secure MICR Printer User’s Guide

34

Print MICR CMC7 Font

&%SM7ddd...ddd$

&%SM7

Lead in sequence

ddd...ddd

Data to be printed in CMC7 font

$

Command terminator


Prints the specified data in the CMC7 MICR font which is used in Europe and South
America. The font and its correct spacing begin at the current cursor position modified by
the MICRpoint adjustment setting at the start of the command. After the terminator is
sent, the printer will return to its default font, and the MICR count will be decremented by
one. Upon receiving this command the printer will check to ensure a MICR toner
cartridge is installed and set the copies parameter to 1. See Appendix B for CMC7
character mapping.

Print Secure Numeric Font

&%SMFddd..ddd~

&%SMF

Lead in sequence

ddd...ddd

Data to be printed in this font

~

Command terminator


The dollar sign ($) is not a command terminator for this command. For both security
fonts the tilde ~ (hex 7E) is the command terminator since the dollar sign is a valid
character.

Print ICR Secure Numeric Font &%SMIxxxxxx~

&%SMI

Lead in sequence

xxxxxxxx

Data variables to be printed in this font

~

Command terminator

Print MicroPrint Line

&%SMMxxxxxxxxx!$

&%SMM

Lead in sequence

xxxxxx

Data to be printed in this font

!

MP designator (optional)

$

Command terminator


If the exclamation point (!) is used, the “MP” designate will print just above and to the
right of the last character. This is optional and is typically used to notify the check
recipient of the presence of MicroPrinting. Only 0-9, A-Z (upper and lower case) print.
Special characters and spaces will disappear.

MICR Features | 6