Source Technologies ST9620 User Manual

Page 52

Advertising
background image

Source Technologies, LLC ST9620 Secure MICR Printer User’s Guide

49

This command identifies the data to be printed in the first column of the report. It is a
maximum of 14 characters in length. If less than 14 characters are sent, the printer fills
the field with spaces when the audit report is printed. This field is only recorded in the
audit report; it is not printed on the check.

Audit Report Field Two-MICR Line &%SMDd..d$ or &%SM7d..d$

&%SMD or &%SM7

Lead in sequence

d..d

Data to be printed

$

Command terminator


This command identifies the data to be printed in the second column of the report. It is a
maximum of 40 characters in length.

Audit Report Field Three

&%SQ3d..d$

&%SQ3

Lead in sequence

d..d

Data to be printed

$

Command terminator


This command identifies the data to be printed in the third column of the report. It is a
maximum of 40 characters.

Audit Report Field Four

&%SQ4d..d~

&%SQ4

Lead in sequence

d..d

Data to be printed

~

Command terminator


This command identifies the data to be printed in the fourth column of the report. It is a
maximum of 16 characters in length. Since a total of this field can be provided at the end
of the Audit Trail Report it is typically used for the convenience amount field.

Note:

This is the only command where the $ is not a command terminator. The

tilde ~ (hex 7E) acts as the command terminator.

Audit Report Field Five

&%SQ5d..d$

&%SQ5

Lead in sequence

d..d

Data to be printed

$

Command terminator


This command identifies the data to be printed in the fifth column of the report. This field
is a maximum of eight characters.

Audit Report Field Six

&%SQ6d..d$

&%SQ6

Lead in string

Audit Trail Reports | 8

Advertising