Full upgrade – Symantec VERITAS STORAGE FOUNDATION HP-UX User Manual

Page 46

Advertising
background image

48 Upgrading the product

Upgrading from 4.1 to 5.0

16 Configure SFCFS on system01 and system02. See

Using the log files

”.

Note: VCS configuration files are not changed during this configuration.

17 Upgrade file systems to proper disk layout version as mentioned in

Upgrading the disk layout versions

” on page 50.

18 Verify that all the file systems are working properly and data is intact.

See

cfsmount

(1M).

19 Run

step 7

,

step 9

, and

step 16

on rest of the nodes to be upgraded.

Full upgrade

Following procedure assumes a 4 node cluster system01, system02, system03,
system04 where all nodes are simultaneously upgraded from 4.1 to 5.0.

1

Log in as superuser.

2

Insert the appropriate software disc into your system's DVD drive.

3

Determine the block device file for the DVD drive:

# ioscan -fnC disk

Make a note of the device file as it applies to your system.

4

Create a directory in which to mount the software disc and mount the disc
using the appropriate drive name. For example:

# mkdir -p /dvdrom

# /usr/sbin/mount -F cdfs /dev/dsk/c3t2d0 /dvdrom

5

Change to the top-level directory on the disc:

# cd /dvdrom

6

Install all the prerequisite patches on all the nodes. See

Required HP-UX

patches

” on page 15.

7

Offline all SFCFS resources on all nodes by running the following
commands on one of the cluster nodes.

# hagrp -offline service_group -sys system01

# hagrp -offline service_group -sys system02

# hagrp -offline service_group -sys system03

# hagrp -offline service_group -sys system04

where service_group is the command that displays the service groups by

hagrp -dep cvm

.