INITIAL SETTING

CAMERA ADDRESS SETUP

Use SW701, SW702, or 703 for Camera Address setup. You may allocate
up to 255 addresses by using SW701 to set the 3rd digit, SW702 the 2nd
digit, and SW703 the 1st digit.
EX) In case of Camera Address 1, see the following figure for setup.

Setting communication Protocol

Use number 1~4 PIN of SW704 to set communication Protocol.

Baud Rate Setting

Use PIN 5 and 6 of SW704.

SW701

SW702

SW703

1 2

3 4 5 6 7 8

ON

OFF

BAUD RATE

4800 BPS

9600 BPS

19200 BPS

38400 BPS

PIN 5

ON

OFF

ON

OFF

PIN 6

ON

ON

OFF

OFF

A : SAMSUNG HALF
B : SAMSUNG FULL

PIN1

PIN2

PIN3

PIN4

A

OFF

OFF

OFF

OFF

B

ON

OFF

OFF

OFF

C

OFF

ON

OFF

OFF

D

ON

ON

OFF

OFF

E

OFF

OFF

ON

OFF

F

ON

OFF

ON

OFF

G

OFF

ON

ON

OFF

H

ON

ON

ON

OFF

I

OFF

OFF

OFF

ON

J

ON

OFF

OFF

ON

K

OFF

ON

OFF

ON

L

ON

ON

OFF

ON

M

OFF

OFF

ON

ON

N

ON

OFF

ON

ON

O

OFF

ON

ON

ON

P

ON

ON

ON

ON

PIN

Comp

(x100) (x10) (x1)

SW704

ON

1 2 3 4 5 6 7 8

SW701 SW702 SW703

SEE INSTRUCTION MANUAL

(BOTTOM VIEW)

SW 704

ADAPTER CONNECTION

SCC-C6407 Adapter BOARD

The factory default setting is set to 9600BPS.

00600A-SCC-C6407-ENG

8/17/06

3:27

PM

˘`

1-9