Troubleshooting / repair parts 5, Repair parts list – Simer Pumps 2905-04 User Manual

Page 5

Advertising
background image

Troubleshooting / Repair Parts

5

For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t start or run.

Blown fuse or breaker.

If blown, replace with fuse of proper size or reset breaker.

Low line voltage.

If voltage under recommended minimum, check size of wiring from
main switch on property. If OK, contact power company or hydro authority.

Defective motor.

Replace pump.

Defective float switch.

Replace float switch.

Float obstructed.

Remove obstruction.

Pump starts and stops

Backflow of water from piping.

Install or replace check-valve.

too often.

Faulty float switch.

Replace float switch.

Pump won’t shut off.

Defective float switch.

Replace float switch.

Restricted discharge

Remove pump and clean pump and piping.

(obstacle in piping).
Float obstructed.

Remove obstruction.

Pump operates but

Low line voltage.

If voltage under recommended minimum, check size of wiring from main

delivers little or no water.

switch on property. If OK, contact power company or hydro authority.

Worn or plugged impeller.

Replace pump.

Anti airlock vent hole is plugged.

Clean out the vent hole with a hat pin or pipe cleaner.

Key No.

Part Description

Qty.

2905-04

2955-04

2957-04

1

Power Cord

1

PS117-54-TSU

PS117-54-TSU

PS117-54-TSU

2

Cover, Motor Assembly

1

**

**

**

3

Inlet Screen

1

PS18-128P

PS18-127P

PS18-127P

4

Switch Assembly

1

FP18-15BD-P2 FP18-15BD-P2

FPS17-66*

REPAIR PARTS LIST

* Replacement vertical switch must be mounted on discharge pipe.
** If the motor fails, replace the pump.

1

2

3

4

5916 0109

1

2

3

4

5918 0109

2905-04
2955-04

2957-04

Advertising
This manual is related to the following products: