THERMOSTAT CONTROL PANEL LOCATION

The Thermostat Control Panel should be outside the box in order to protect it and to
allow observation of the indicator lamp. The length of the sensing tube dictates the
location, as it must reach the plate. The maximum length of this tube is 40" (180 mm.)
(The sensing tube must be attached to the refrigerator plate in a multiple plate system.)
Mount the Thermostat in a location where the wires and sensing tube can be led. Use
the cut out template packed with the Thermostat Control Panel. The harness on the
Thermostat Control Panel may be spliced with 16-gauge wire.


ELECTRICAL JUNCTION BOX

The DC 5000 is equipped with a 4' (105 cm.) harness that is to connect to the Electrical
Junction Box. Do not splice this harness. Position the Electrical Junction Box to
allow proper routing of the harness. If the electrical junction box is closer than 4 feet,
shorten the harness.

Large battery supply cables, (See wire sizes) the thermostat control harness, and water
pump harness will all connect at the electrical junction box.