Manager mode, Maintenance mode, Anager – Star Trac E-TBT User Manual

Page 25: Aintenance

Advertising
background image

STAR TRAC E SERIES TOTAL BODY TRAINERS O

WNER

S

M

ANUAL

25

After using your STAR TRAC E SERIES TOTAL BODY TRAINERS for a period of time, you may wish to change some of its settings.

MANAGER MODE

The Manager Mode allow you to query and modify the basic settings of your Total Body Trainer. To enter Manager Mode:

1.

Press and hold the

,

and keys

together.

2.

A beep will sound and “MANAGER MODE” will display momentarily in the Message Window.

3.

Release all keys. “SERIAL NO #####” will display in the Message Window.

NOTE: The system will automatically exit Manager Mode if no key is pressed for 30 seconds.

The following keys are used to modify settings in MANAGER MODE:

Upper and Lower Data Information Window S

CROLL

Keys: Display the next and previous parameters, respective-

ly.

Increase and Decrease L

EVEL

Keys: Adjust the value of the displayed parameter up and down, respectively, in incre-

ments of 1 unit . These keys do not save the new value - see OK Key below.

OK Key: Updates (saves) the values of all parameters in Flash memory, and exits Manager Mode.

NOTE: To exit Manager Mode without saving any values or settings, press the Q

UICK

S

TART

key.

The items that you may display and change with the previous keys are:

MAINTENANCE MODE

Your Service Representative may need to check accumulated data about the past usage of your STAR TRAC E SERIES TOTAL BODY
TRAINER
, test its display controls, or investigate error messages. For these reasons, your Total Body Trainer is equipped with a
Maintenance Mode. The Maintenance Mode includes all of the items available through Manager Mode, plus additional items for Service
and Diagnostic use. To enter Maintenance Mode:

1.

Press and hold the

,

and keys

together.

2.

A beep will sound and “MAINTENANCE MODE” will display momentarily in the Message Window.

3.

Release all keys. “SERIAL NO #####” will display in the Message Window.

M

ANAGER

/ M

AINTENANCE

M

ODE

Lowest

Highest

Default

Item

Value

Value

Value

Meaning

Serial No

0

65535

0

Serial number (set by factory)

Date

01/00

12/99

01/05

Manufacture date for the Total Body Trainer (set by factory)

Display Vers 1

01.00

99.99

N/A

Display panel software version (set by factory)

Display Vers 2

01.00

99.99

N/A

Display panel software version (set by factory)

LCB Vers

01.00

99.99

N/A

Display panel software version (set by factory)

Units

English

Metric

English

English = units of pounds, miles, feet, inches;

Metric = units of kilograms, kilometers, centimeters.

Time

5

99

99

Maximum time in minutes allowed for program, excluding warm-up and cool-
down.

Weight

50 (Lb)

350 (Lb)

350 lbs

Default (to user), typical weight in lb (UNITS=English), or kg

22 (KG)

158 (KG)

158 (KG)

(UNITS=Metric).

Language

N/A

N/A

ENGL

Language is English (ENGL), Dutch (DUTC), French (FREN), German (GERM),
Portuguese (PORT), Spanish (SPAN), Swedish (SWED), Italian (ITAL) or
Katakana (KATA).