Southbend Gearhead w/ Dro SB10146PF User Manual

Page 33

Advertising
background image

For Machines Mfg. Since 3/11

Turn-Nado

®

Gearhead Lathes

-31-

P R E P A R A T I O N

Disconnect power supply! Electrocution

could occur if you attempt this procedure

with the power wires connected to the power

source. The incoming power wires must be

disconnected from power before performing

this procedure.

L3

L2

L1

To Power

Supply

Hot

MASTER

POWER SWITCH

Hot

Hot

Ground

Figure 23. Power connection at master power switch.

4. Make sure the wires have enough slack so

that they do not bind at the terminals.

5. Close and lock the electrical cabinet door.

3. Connect the incoming hot wires to the

master power switch terminals and connect

the ground wire to the ground terminal, as

illustrated in Figure 23.

Connecting Power

1. Make sure the master power switch is

turned to the OFF position, then open the

electrical cabinet door.

2. Refer to Figure 22 to identify the master

power switch and the hole at the bottom left

for the incoming power supply.

To avoid unexpected start-up of lathe

components, keep the master power switch

turned OFF until instructed otherwise in the

Test Run.

Figure 22. Electrical cabinet.

Master

Power

Switch

Incoming Power Strain Relief

Advertising