Home Alarm
Connections

Illus. 6

M O D E L I C B 4 3 0

I N S T A L L A T I O N I N S T R U C T I O N S

IMPORTANT NOTE: If you are not responsible
for alarm system connection, this information
should be supplied to the home security system
contractor.

H O M E A L A R M

C O N N E C T I O N S

Before the kickplate and grille are installed, all
necessary wiring connections in the compres-
sor compartment should be completed.

If a home alarm system is to be installed on
the Wine Storage unit, the connections should
be made using the logic supplied with the
alarm specifications. See illustration 6 below
for the appliance lead locations, and refer to
the following for color codes:

Normally open contacts – white with red
stripe wire

Normally closed contacts – white with blue
stripe wire

Common – gray with white stripe wire

Use the 6 mm spade terminals or wire nuts
provided to make the proper wiring connec-
tions.

The alarm circuit in the unit is intended as
a low-voltage, low-current device only. It
should not be used to switch line power.

Any unused terminals should be
completely insulated and all wires should
be secured away from conductive or
moving components.