Soleus Air LX-140 User Manual

Page 11

Advertising
background image

11

c)

Turn on the unit by pressing the On/Off Button on the control panel.

d)

Press the Mode Button until the “

” appears on the VFD display.

e)

Select the fan speed by using FAN button.

During the AUTO model, the unit operates at heating mode when the room temperature is below 68

o

F

degree. It operates at dehumidifying mode when the room temperature is between 68

o

F to 80

o

F degree.

It operates at cooling mode when the room temperature is above 80 degree. You may use the timer with
the AUTO mode.

6)

Sleep Mode (This Mode is available when using Remote control )


a)

The air conditioner is in operation

b)

Press SLEEP Button, the “

” appears on the VFD.

c)

The fan motor of indoor unit runs in low speed



d)

When in cooling mode, within the first two hours, the temperature will be increased 1℉
per hour. Then temperature will be keeping at 2℉ higher than the originally set degree
for 6 hours. 6 hours later, temperature will return to the originally set degree.

e)

When in heating mode, within the first 2 hours, temperature will be decreased 1℉ per
hour. Then temperature will be keeping at 2℉ Lower than the original degree for 6
hours.6 hours later, temperature will return to original degree you set.

g) When in dehumidify mode, the temperature will not be changed.

NOTE: When the room temperature is low and the indoor humidity is high, the condensate of the air
conditioner may not be discharged in time. Water will accumulate in the unit that leads to the unit stops

working automatically for a long time. (At the moment, the “

” appears on the VFD display.) In

order to let your unit recover working quickly, you can pull out the “Drain Port” which is located in the
lower left bottom of the back of the unit. The condensate will be discharged several minutes after water
be drained. Please use at least 1.5 liter pan to catch the dripping water.
It is not advised to use continuous drain method when the room temperature is higher than 90℉.

Advertising