3) SSP register access method

Access to SSP break address register is performed through the tem-
porary register as shown below:

Fig. 6-5

Enable flags can be accessed individually.
Though enable register

can be accessed individually, writing to

brake address registers

and

is performed at the same time as

writing to brake address register

through the temporary register.

Therefore, set

and

to temporary, then write into

at last.

Since the temporary register is commonly used by BAR sets, thefol-
lowing register setting is performed after completion ofsetting of each
break address register.

SSP control method

Access to the enable register and the brake address register is only
possible when writing to them from the CPU.

Information on which brake register the SSP brake is detected in is
read as binary data by reading address FFFFFFH (*1).
Used in an expanded register.
Normally is a reserve bit. Whenreading, fixed to 0.
If there are 32 break registers, binary expression is made with the
above 5 bits, and 0th is “00000

B

” and 31st is “11111

B

.”

When detected simultaneously by two or more break registers,
onewith the smaller BAR number is read as binary data.
The brake signals (NMI) and the above detection data (CMP0~4)
areheld until the above detection data are read. So read should be-
made in the NMI sub routine. (Clear by FFFFFFH read.)

1: FFFFFFH is not fulldecoded. (FFFF00H~FFFFFFH). There-

fore,unnecessary read access in parentheses should not be
performed.

1

2

3

4

A19 A18 A17 A16 A15

A8

A7

A2

EN

WR

WR

Temporary

Temporary

bit 7

6

5

4

3

2

1

0

0

0

CMP4

0

CMP3 CMP2 CMP1 CMP0 (FFFFFFH)

7. PRINTER control circuit

1) Block diagram

Fig. 7-1

2) General description of the printer controller

The DP-730 is used as the R/J printer. The printer mechanical timing
control is made by the CPU through MPCA7.

3) Printer motor drive circuit

When the MTD is high, the motor rotates.
When the MTD is low, the motor stops.

CPU

Data
bus

MPCA7

DRIVER

PRINTER
(DP-730)

RECEIVER

Address bus

MTD

MPCA7

M

Speed limiter
circuit

2.2K

R128

+24V

C92

DP

Normal 555µs (516~590µs)

Main PWB side

Printer side

R127

COM

Q7

C227

MTD

DP

4 – 13

Advertising