Status register, Table 24: status register – Silicon Image SiliconDrive SSDS00-3650H-R User Manual

Page 34

Advertising
background image

S

ILICON

S

YSTEMS

P

ROPRIETARY

This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.

All unauthorized use and/or reproduction is prohibited.

P

AGE

22

J

UNE

17, 2008

D

OCUMENT

: 3650H-02DSR

SSD-H

XXX

(I)-3650 D

ATA

S

HEET

ATA R

EGISTERS

S

TATUS

R

EGISTER

The Status register provides the device’s current status to the host. The status
register is an 8-bit read-only register. When the contents of the register are
read by the host, the IREQ# bit is cleared.

Table 24: Status Register

Operation

D

7

D

6

D

5

D

4

D

3

D

2

D

1

D

0

Read/Write

BSY

DRDY

DWF

DSC

DRQ CORR

IDX

ERR

Default Value

0

0

0

0

0

0

0

0

Bit(s)

Description

7

Busy (BSY).

Set when the drive is busy and unable to process any

new ATA commands.

6

Data Ready (DRDY).

Set when the device is ready to accept ATA

commands from the host.

5

Drive Write Fault (DWF).

Always set to 0.

4

Drive Seek Complete (DSC).

Set when the drive heads have been

positioned over a specific track.

3

Data Request (DRQ).

Set when a device is ready to transfer a word

or byte of data to or from the host and the device.

2

Corrected Data (CORR).

Always set to 0.

1

Index (IDX).

Always set to 0.

0

Error (ERR).

Set when an error occurs during the previous ATA

command.

Advertising