TWO TEMPERATURE-ONE HEATER HIGH TEMPERATURE STORAGE

WITH RECIRCULATION OF SANITIZING LOOP

NOTE 1: TOGGLE SWITCH CONTROLS 180°F WATER CIRCULATION.

INSTALL ON OR CLOSE TO DISHWASHING MACHINE .
TOGGLE SWITCH MUST BE CLOSED (ON) DURING THE
RINSE OPERATION AND OPEN (OFF) WHEN DISHWASHER
IS NOT OPERATING.

NOTE 2: INSTALL LINE TEMPERATURE CONTROL IN AN

UNINSULATED TEE BEYOND THE DISHWASHING
MACHINE TAKEOFF IN THE SANITIZING LOOP. CONTROL
SHOULD BE SET AT 185°F (85°C).

NOTE 3: ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW

RATE DOES NOT CAUSE UNNECESSARY TURBULENCE
IN THE TANK.

NOTE 4: IF TEMPERED WATER IS RECIRCULATED, RETURN LINE

SHOULD BE CONNECTED AT POINT "A".

WIRING DIAGRAM FOR 180° LOOP (IF USED)

INSET A

INSTALL THERMAL EXPANSION
TANK IN COLD WATER SUPPLY
LINE, IF CHECK VALVE OR
PRESSURE REDUCING VALVE IS
USED IN SUPPLY.

INSET B

VACUUM RELIEF VALVE

INSTALL PER LOCAL CODES.

NOTES