Features and specifications – State Industries GPO 86-199 User Manual

Page 2

Advertising
background image

2

TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION
RELATIVE TO YOUR SAFETY. PLEASE READ THOROUGHLY BEFORE
USING APPLIANCE.

This is a typical oil-fired heater for commercial water heating applications.

The principal components of the heater are shown and identified here.
The identification plate illustrations on page 4 interpret certain markings
into useful information. Use these reference to identify the heater and its

components

FEATURES AND SPECIFICATIONS

FIGURE 1

TABLE 2 RECOVERY CAPACITIES, based on 80% efficiency

TANK

APPROX

U.S Gallons/Hr. and Litres/Hr at TEMPERATURE RISE INDICATED

CAPACITY

EFF.

40F°

50F°

60F°

70F°

80F°

90F°

100F°

110F°

120F°

130F°

140F°

Model

Btuh

KW

U.S.Gal. Litres

%

22.2C°

27.7C°

33.3C°

38.8C°

44.4C°

50C°

55.5C°

61.1C°

66.6C°

72.2C°

77.7C°

GPO

199,000

86

80

GPH

477

381

318

272

238

212

191

173

159

147

136

86-199

58

326

LPH

1804

1443

1203

1031

902

802

722

656

601

555

516

GPO

245,000

86

80

GPH

587

469

391

335

293

261

235

213

196

181

168

86-245

72

326

LPH

2221

1777

1481

1269

1111

987

889

808

740

683

635

GPO

315,000

84

80

GPH

754

604

503

431

377

335

302

274

251

232

216

84-315(A)

92

318

LPH

2856

2285

1904

1632

1428

1269

1142

1039

952

879

816

GPO

385,000

75

80

GPH

922

738

615

527

461

410

369

335

307

284

263

75-385(A)

113

284

LPH

3491

2793

2327

1995

1745

1551

1396

1269

1164

1074

997

GPO

455,000

75

80

GPH

1090

872

727

623

545

484

436

396

363

335

311

75-455(A)

133

284

LPH

4125

3300

2750

2357

2063

1833

1650

1500

1375

1269

1179

GPO

700,000

69

80

GPH

1677

1341

1118

958

838

745

671

610

559

516

479

69-700(A)

205

261

LPH

6347

5077

4231

3627

3173

2821

2539

2308

2116

1953

1813

ALL DIMENSIONS IN INCHES/mm
*Model numbers followed by the suffix "A" indicates the optional A.S.M.E. tank construction.

TABLE 1 NOMINAL MODEL DIMENSIONS

GPO 86-199

GPO 86-245

GPO 84-315(A)

GPO 75-385(A)

GPO 75-455(A)

GPO 69-700(A)

Dim.

Inches

mm

Inches

mm

Inches

mm

Inches

mm

Inches

mm

Inches

mm

A

74 1/2

1,892

74 1/2

1,892

74 1/2

1,892

73 3/4

1,873

73 3/4

1,873

73 3/4

1,873

B

36 3/4

933

36 3/4

933

36 3/4

933

36 3/4

933

36 3/4

933

36 3/4

933

C

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

27 3/4

705

D

2

51

2

51

2

51

2

51

2

51

2

51

E

3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT

F

8

203

8

203

8

203

8

203

8

203

10

254

G

26 5/8

676

26 5/8

676

26 5/8

676

24 3/4

629

24 3/4

629

30 3/16

767

H

74 1/2

1,892

74 1/2

1,892

74 1/2

1,892

73 3/4

1,873

73 3/4

1,873

79 3/16

2,011

J

1 1/2 NPT 1 1/2 NPT 1 1/2 NPT 1 1/2 NPT 1 1/2 NPT 1 1/2 NPT

K

1 1/2 NPT 1 1/2 NPT 1 1/2 NPT 1 1/2 NPT 1 1/2 NPT 1 1/2 NPT

L

22 3/4

578

22 3/4

578

22 3/4

578

23 7/16

595

23 7/16

595

28 7/8

733

Approx.

Shipping

553

251

554

252

554

252

624

283

700

318

739

335

Weight STD.

Lbs

Kg.

Lbs.

Kg.

Lbs.

Kg.

Lbs.

Kg.

Lbs.

Kg.

Lbs.

Kg.

Approx.

Shipping

657

298

742

337

747

339

822

373

Weight ASME

---

---

---

---

Lbs.

Kg.

Lbs.

Kg.

Lbs.

Kg.

Lbs.

Kg.

Model

* All tanks are tested at 320 psig working pressure.
** Based on No. 2 fuel oil with a heat content of 140,000 Btu's per gallon at 80% thermal efficiency. Above 2,000 altitude, input
ratings should be reduced 4% for each 1000' above sea level.