Symptoms

Probable Cause

Recommended Action

C.

Pressure difference greater than

5 psi (34.5 kPa) between the hot

and cold supply lines.

C.

Install pressure regulators to bring

the supplies with 5 psi (34.5 kPa)

of each other.

D.

If none of the recommended

actions for the above issues

correct the symptom, the valve

requires servicing.

D.

Contact your Kohler Co. authorized

service representative.

10.

Water leaking from the

valve.

CAUTION: Risk of
personal injury or
product damage.

Turn off

the main power and

water supply.

A.

Connections are not secure.

A.

Check all connections. Make

adjustments as needed.

B.

Seals are worn or damaged.

B.

Order a seal service pack and

replace all seals.

C.

Internal leak.

C.

Unit requires overhaul. Contact

your Kohler Co. authorized service

representative.

11.

Hot water only, the valve

shuts down.

A.

Hot and cold lines are reversed.

A.

Switch hot and cold water supply

connections. Verify the hot water

supply is connected to the inlet

marked

″H″ and the cold water

supply is connected to the inlet

marked

″C.″