Troubleshooting Procedures (cont.)

Symptoms

Probable Causes

Recommended Action

E.

Control does not work.

E.

Replace the control. Refer to your

installer or wholesale dealer.

3.

User keypad is

illuminated, but does not

respond to buttons or

outer ring.

A.

Control program is locked.

A.

Reset GFCI or RCD.

B.

P5 plug assembly harness from

user keypad to control is loose,

disconnected, or damaged.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary. Refer to your

installer or wholesale dealer.

C.

User keypad does not work.

C.

Replace the user keypad. Refer to

your installer or wholesale dealer.

D.

Control does not work.

D.

Replace the control. Refer to your

installer or wholesale dealer.

4.

Blower motor will not

start.

A.

No water in the bath.

A.

Fill the bath at least 2

″ (5 cm)

above the top of the highest air jet.

B.

Power cord from blower motor

to control is loose, disconnected,

or damaged.

B.

Check wiring for proper

connections.

C.

Blower motor does not work.

C.

Replace the blower motor. Refer to

your installer or wholesale dealer.

D.

Control does not work.

D.

Replace the control. Refer to your

installer or wholesale dealer.

5.

Blower motor stops

running and will not

immediately restart.

Keypad is illuminated.

A.

Blower motor overheated and

protection device activated.

A.

Check for blockage at motor vents.

Remove blockage and allow motor

to cool. Refer to dealer or

wholesale distributor. Otherwise,

refer to

″User keypad is

illuminated, but does not respond

to buttons or outer ring.

6.

Blower motor starts, some

but not all airjets are

bubbling.

A.

Blower motor speed is too low.

A.

Increase speed setpoint to blower

motor.

B.

Blower motor inlet is blocked.

B.

Clean blower motor inlet.

C.

Blower motor does not work.

C.

Replace the blower motor. Refer to

your installer or wholesale dealer.

D.

Blower motor discharge is

blocked.

D.

Check blockage.

E.

Check valve does not work.

E.

Replace the check valve. Refer to

your installer or wholesale dealer.

F.

Airjets are clogged.

F.

Use a small between-the-teeth

dental brush and white vinegar.

Dip the brush in the vinegar, brush

the hole, rinse the brush in clean

water, and then use the wet rinsed

brush to rinse the hole.

7.

Blower motor runs but no

air bubbles are formed.

A.

Blower motor inlet is blocked.

A.

Clean blower motor inlet.

B.

Airjets are clogged.

B.

Use a small between-the-teeth

dental brush and white vinegar.

Dip the brush in the vinegar, brush

the hole, rinse the brush in clean

water, and then use the wet rinsed

brush to rinse the hole.

C.

Check valve does not work.

C.

Replace the check valve. Refer to

your installer or wholesale dealer.