Troubleshooting Procedures (cont.)

Symptoms

Probable Causes

Recommended Action

D.

Blower motor does not work.

D.

Replace the blower motor. Refer to

your installer or wholesale dealer.

E.

Control does not work.

E.

Replace the control. Refer to your

installer or wholesale dealer.

8.

Blower motor operates,

air bubbles are formed,

zone controls work, but

variable speed feature

does not work.

A.

Blower motor inlet is blocked.

A.

Clean blower motor inlet.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary. Refer to your

installer or wholesale dealer.

C.

User keypad does not work.

C.

Replace the user keypad. Refer to

your installer or wholesale dealer.

D.

Blower motor does not work.

D.

Replace the blower motor. Refer to

your installer or wholesale dealer.

E.

Control does not work.

E.

Replace the control. Refer to your

installer or wholesale dealer.

9.

Blower motor won’t turn

off when the power

button on user keypad is

pressed.

A.

User keypad does not work.

A.

Replace the user keypad. Refer to

your installer or wholesale dealer.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary. Refer to your

installer or wholesale dealer.

C.

Control does not work.

C.

Replace the control. Refer to your

installer or wholesale dealer.

10.

A zone does not produce

air bubbles but another

zone operates normally.

A.

Zone is not selected.

A.

Select the zone according to the

instructions in

″User Keypad and

Bath with Airjets Modes/Features.

B.

Butterfly valve does not work.

B.

Replace the butterfly valve. Refer

to your installer or wholesale

dealer.

C.

Loose, disconnected, or

damaged wiring harness.

C.

Check wiring for proper

connections. Replace the wiring

harness if necessary. Refer to your

installer or wholesale dealer.

D.

User keypad does not work.

D.

Replace the user keypad. Refer to

your installer or wholesale dealer.

E.

Control does not work.

E.

Replace the control. Refer to your

installer or wholesale dealer.

11.

Surge mode does not

work.

A.

User keypad does not work.

A.

Replace the user keypad. Refer to

your installer or wholesale dealer.

B.

Control does not work.

B.

Replace the control. Refer to your

installer or wholesale dealer.

12.

Water spillage or damage

observed under the bath.

A.

Drain or overflow leaking.

A.

Repair or replace the drain

assembly according to the

manufacturer’s instructions.

B.

Wall, deck, and/or shower door

is improperly sealed.

B.

Apply silicone sealant at the seams

between the bath and the wall,

deck, or door.

C.

Cracked acrylic air channels.

C.

Refer to the manufacturer.

1038265-5-B

12

Kohler Co.

Advertising